International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original Papers
Study of Cavitation Instabilities in Double- Suction Centrifugal Pump
Shinya HatanoDonghyuk Kang Shusaku KagawaMotohiko NohmiKazuhiko Yokota
著者情報
ジャーナル フリー

2014 年 7 巻 3 号 p. 94-100

詳細
抄録
In double-suction centrifugal pumps, it was found that cavitation instabilities occur with vibration and a perio dic chugging noise. The present study attempts to identify cavitation instabilities in the double-suction centrifugal pump by the experiment and Computational Fluid Dynamics (CFD). Cavitation instabilities in the tested pump were classified into three types of instabilities. The first one, in a range of cavitation number higher than breakdown cavitation number, is cavitation surge with a violent pressure oscillation. The second one, in a range of cavitation number higher than the cavitation number of cavitation surge, is considered to be rotating cavitation and causes the pressure oscillation due to the interaction of rotating cavitation with the impeller. Last one, in a range of cavitation number higher than the cavitation number of rotating cavitation, is considered to be a surge type instability.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2014 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
前の記事 次の記事