International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original Papers
PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan
Toru ShigemitsuHiroaki FukudaJunichiro Fukutomi
著者情報
ジャーナル フリー

2016 年 9 巻 2 号 p. 175-181

詳細
抄録
Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2016 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
前の記事 次の記事
feedback
Top