Industrial Health
Online ISSN : 1880-8026
Print ISSN : 0019-8366
ISSN-L : 0019-8366
Original Articles
Evaluation of performance loss of paraffin oil loaded filtering facepieces
Francesca TOMBOLINI Stefano LISTRANIAntonella CAMPOPIANOCarmela PLEBANI
著者情報
ジャーナル フリー

2016 年 54 巻 5 号 p. 403-409

詳細
抄録

Penetration measurements through commercially available filtering facepieces were performed with monodisperse DEHS aerosols ranging from 0.03 μm to 0.40 μm (either singly charged or neutralized), before and after 500 mg of paraffin oil loading. The distinct behavior of Coulomb and polarization capture efficiency is studied: as in the case of non loading also in the case of loading 500 mg of paraffin oil, the electrostatic capture mechanisms are mainly due to the Coulomb contribution up to aerosol particle diameter of about 0.10 μm, just when the polarization contribution becomes substantial. Both Coulomb and polarization capture mechanisms are influenced by the presence of 500 mg of paraffin oil, resulting less effective than the oil unloaded case of about 12% and 11%, respectively. By the occupational hygiene point of view, there is a degradation in the filter performance due to oil loading that the user does not realize because there is no remarkable variation in the breathing resistance.

著者関連情報
© 2016 by National Institute of Occupational Safety and Health
前の記事 次の記事
feedback
Top