Accuracy of metabolic rate estimates from heart rate under heat stress—an empirical validation study concerning ISO 8996
Peter BRÖDEBernhard KAMPMANN
著者情報
ジャーナル フリー 早期公開

論文ID: 2018-0204

この記事には本公開記事があります。
詳細
抄録

The standard ISO 8996 provides methods for the determination of metabolic rate from measured oxygen consumption (MVO2), as well as simplified estimation algorithms based on heart rate (MHR). We quantified the accuracy of these methods by comparing MHR with MVO2 measured in 373 climatic chamber experiments under different workloads and widely varying heat stress conditions. While our results confirmed the 5% accuracy level for MVO2, MHR considerably overestimated MVO2 due to the rise in core temperature concomitantly increasing heart rate by approximately 30 bpm/°C resulting in an overall error of 43%. After individually correcting for this bias the accuracy was 10–15% as stipulated by the standard. Thus, methods correcting for the thermal component of heart rate, e.g. by introducing intermittent resting periods of sufficient length of at least five minutes when investigating heat stress at workplaces, should become a mandatory element in the ongoing revision of the relevant standards.