Internal Medicine
Online ISSN : 1349-7235
Print ISSN : 0918-2918
ISSN-L : 0918-2918

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Usefulness of a Pulse Oximeter and Multimodality Imaging for Diagnosing Platypnea-orthodeoxia Syndrome
Ryo AbeMike SajiYuki IzumiItaru TakamisawaKanako KishikiSatonori MaekawaraYuji NagatomoSatoshi YazakiMamoru NanasatoMitsuaki Isobe
著者情報
ジャーナル オープンアクセス 早期公開

論文ID: 0159-22

この記事には本公開記事があります。
詳細
抄録

Platypnea-orthodeoxia syndrome (POS) is a rare disease characterized by dyspnea and hypoxemia in orthostatism that improves in the recumbent position. We herein report an 81-year-old woman with dyspnea in the upright position following thoracic vertebral compression fractures. After the patient's daughter brought a recording showing decreasing SpO2 (peripheral capillary oxygen saturation) in the upright position as measured by a portable pulse oximeter outside the hospital, a small atrial septal defect (ASD) was detected. A contrast echocardiogram and four-dimensional flow magnetic resonance imaging demonstrated a right-to-left shunt. The patient's symptoms dramatically improved after percutaneous ASD closure. In conclusion, such new technologies are useful for diagnosing POS.

著者関連情報
© 2022 by The Japanese Society of Internal Medicine
feedback
Top