Proceedings of the JFPS International Symposium on Fluid Power
Online ISSN : 2185-6303
ISSN-L : 2185-6303
SURGE IN A PRESSURE-COMPENSATED POSITIVE DISPLACEMENT VANE-PUMP
Hisanori UENOAtushi OKAJIMAYoshihiro OJITakanori HONDA
著者情報
ジャーナル フリー

1996 年 1996 巻 3 号 p. 85-90

詳細
抄録
In this paper, we revealed a factor causing the remarkably large amplitude delivery-pressure oscillation with quite low frequency, occurring often in pressure-compensated variable displacement vane pumps under deadhead conditions. It was found experimentally and theoretically that the pump instability originates in the fact that the gradient, ∂A/∂E is significantly negative, where A is time-averaged effective area for the internal pressure compensation force and E is the cam ring eccentricity. Also this phenomenon is regarded as same as surging of the turbo-fan.
著者関連情報
© The Japan Fluid Power System Society
前の記事 次の記事
feedback
Top