Journal of Asian Architecture and Building Engineering
Online ISSN : 1347-2852
Print ISSN : 1346-7581
Environmental Engineering
Analyses on Thermal Insulation Performance of Earth-Covered Wall for Residential Underground Space by Using a Numerical Simulation Program
Byungseon Sean KimKwangho Kim
著者情報
ジャーナル フリー

2004 年 3 巻 2 号 p. 259-266

詳細
抄録
The purpose of this study is to provide the regional insulation criterion of earth-covered walls for underground residential buildings in Korea by using a numerical simulation program. This study was started from the idea that thermal condition of underground residential space must be closer to that of aboveground residential space. According to the result of this study, the underground temperature declines as the depth from the ground level goes deeper and closer to about 9m, and then maintain some steady value from about 9m of the depth. The minimum thermal insulation by depths was deduced by finding the U-factors that make the inside-surface temperature of the earth-covered wall closer to that of the aboveground wall.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2004 Architectural Institute of Japan
前の記事 次の記事