日本気管食道科学会会報
Online ISSN : 1880-6848
Print ISSN : 0029-0645
ISSN-L : 0029-0645
症例報告
Press Through Packageによる声門異物の一例
中平 光彦中谷 宏章松本 州司竹田 泰三
著者情報
キーワード: PTP, 気道, 異物
ジャーナル 認証あり

2000 年 51 巻 1 号 p. 36-39

詳細
抄録
There have been only a few reports of patients with press through package (PTP) foreign bodies in the airway compared with PTPs found in the esophagus. We experienced a case with a PTP foreign body between the bilateral vocal cords. The PTP was safely removed from the larynx using a forceps through a flexible fiberscope. In our case, the time elapsed from the PTP entering the larynx to its detection was within one day. However, the detection of a PTP foreign body in the respiratory system usually requires more time. According to a review of the literature, 50% of such patients needed over three days after the onset of aspiration. On the other hand, PTP foreign bodies in the esophagus, as opposed to the respiratory system, are usually discovered within three days in over 90% of patients. The difference in the time required for detection of PTPs seems to be related to the severity of symptoms and the anatomical differences between the airway and the esophagus. Generally, the symptoms of PTP foreign bodies in the airway are mild and their detection is difficult, especially below the subglottic region, because a PTP is rediolucent. Therefore, detailed information about a patient's recent history and intensive observation by laryngo-tracheal fiberscope are important.
著者関連情報
© 2000 特定非営利活動法人 日本気管食道科学会
前の記事 次の記事
feedback
Top