抄録
Thermoelectric hydrogen sensor (THS) is a promising candidate for a hydrogen leak alarm system because of its unique, reliable working principle and its performance has been improved by fabricating it as a micro-device. In this study, we have investigated the performance of a micro-THS with new design of 4×4 mm2 chip. The integration of a thermoelectric thin film of B-dope SiGe and a ceramic catalyst of Pt 40 mass% loaded alumina into a micro hot-plate on a thin membrane, has improved its performance. We have demonstrated that the micro-THS detected the wide range of H2 concentration in air from low as 0.5 ppm to high as 5 vol%.