A high-sensitivity laser absorption spectroscopic technique has been employed for measurements of the stable carbon isotope ratio of carbon dioxide (CO2), 13CO2/12CO2, in automobile exhaust. The amounts of 12CO2 and 13CO2 were detected through wavelength modulation spectroscopy using a distributed feedback laser diode in the 2-μm wavelength region. A 0.15-L one-pass optical cell with an effective optical path length of 0.5 m was used for continuous measurements of automobile exhaust, with the intention of maintaining the residence time to less than 5 s. In addition, a 0.9-L Herriott-type multi-pass optical cell with an effective optical path length of 29.9 m was used for precise measurements of the stable carbon isotope ratio of CO2 in automobile exhaust, which was collected in a sampling bag. Continuous measurements of the stable carbon isotope ratio were performed with a reproducibility of 0.28 ‰ (1σ) in 14.8 % CO2 for every 1-s signal measurement without signal integration over an 1830 s period. The feasibility of the developed system was evaluated for continuous measurements of the CO2 stable carbon isotope ratio in automobile exhaust. Resultantly, we successfully performed continuous measurements of the stable carbon isotope ratio of CO2 in automobile exhaust and found that the stable carbon isotope ratio of CO2 changed in accordance with the driving conditions.