鉄鋼材料の水素含有量の電気化学測定法におけるニッケル被覆法の開発
軟鋼および鉄単結晶の水素吸蔵現象に関する研究 (第1報)
吉沢 四郎鶴田 孝雄山川 宏二
著者情報
ジャーナル フリー

1975 年 24 巻 10 号 p. 511-515

詳細
抄録
In the conventional electrochemical method determining hydrogen content in iron and steel, a thin palladium layer is electrodeposited on the one side of specimen in order to prevent the passivation of steel and to promote ionization reaction of hydrogen. However, it is very difficult to obtain a uniform deposition layer of palladium and the undeposited or bare part of the surface requires the passivation current of order of 1-2μa/cm2, reducing the accuracy of hydrogen measurement. Nickel deposition was found to be much advantageous and its passivation current was less than 0.1μa/cm2. The suitable thickness of electrodeposited nickel was 500-1000Å. The range of electrode potential for ionizing hydrogen was found to be -0.1-0.3 volt vs. SCE in 1N NaOH solution. In this potential region, the surface of electrodeposited nickel layer is probably covered by Ni3O4 or Ni2O3 through which however hydrogen atoms can permeate.