低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
解説
大型低温重力波望遠鏡(LCGT)における真空技術と断熱技術
大森 隆夫高田 聡佐藤 吉博齊藤 芳男高橋 竜太郎
著者情報
ジャーナル フリー

2011 年 46 巻 7 号 p. 408-414

詳細
抄録
The Large-scale Cryogenic Gravitational wave Telescope (LCGT) requires ultrahigh vacuum tubes, through which laser beams passed. Two 3-km vacuum tubes are kept at a vacuum pressure of ~10-7 Pa so as to reduce the scattering effect caused by residual gas molecules. The mirrors of the main interferometer are cooled to 20 K to reduce thermal noise. The evacuated multi-layer insulation (MLI) consists of organic films with aluminum coatings, which are generally used as thermal insulation for cryostats. We found a lightweight MLI film that has a low out-gassing rate comparable to that of the buffed surface of stainless steel.
著者関連情報
© 2011 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)
前の記事 次の記事
feedback
Top