抄録
Measurements have been made of the heat transfer in liquid helium II in a capillary glass tube with an inside diameter of 93.3μm and a length of 8.5cm. Heat supplied to a lower part of a cell produced a thermal counterflow in the tube. The temperature difference (ΔT) across the tube was measured using a thermocouple (Au [0.03 at% Fe]-Nb⋅Ti) with a SQUID detector. The obtained value of the critical vortex line density (L0)c associated with the transition from a turbulent flow to a laminar flow was larger than that given by Vinen.