低温工学
Online ISSN : 1880-0408
Print ISSN : 0389-2441
ISSN-L : 0389-2441
超電導マグネットの予冷
佐藤 新太郎加藤 重雄尾形 久直
著者情報
ジャーナル フリー

1968 年 3 巻 2 号 p. 64-71

詳細
抄録
Cool down processes of superconducting magnets combined with refrigeration systems are considered. Cool down time may be important in operation of superconducting magnets.
It is shown that cool down time is calculated by a few parameters which are weight of magnets, heat inputs to magnets, efficiency of heat transfer between magnets and cooling fluid, and power of refrigeration systems. Graphical charts to estimate cool down time immediately are represented as a result of the calculation.
Refrigeration systems are as follows: from ambient temperature to near 90°K cooling by helium gas cooled by liquid nitrogen, afterwards to near 20°K helium gas refrigerators are used, finally liquid helium is transferred to vessels of magnets.
著者関連情報
© 社団法人低温工学協会
前の記事 次の記事
feedback
Top