中国・四国整形外科学会雑誌
Online ISSN : 1347-5606
Print ISSN : 0915-2695
ISSN-L : 0915-2695
原著
臼蓋に著明な Osteolysis を生じ再置換術を施行した10例
中前 稔生重信 隆史高橋 和寛岩森 洋
著者情報
ジャーナル 認証あり

2006 年 18 巻 2 号 p. 265-269

詳細
抄録

Polyethylene wear is one of the most important problems of total hip arthroplasty. We reported 10 cases of revision THA because of large bone absorption of acetabulum due to osteolysis. The patients underwent initial THA with the Kyocera Perfix between January 1997 and January 2000. The liners were not made of cross-linked polyethylene. The patients were 3 men and 7 women with an average age at operation of 66 years (range, 45 -80 years). The average period from the initial THA to the revision was 74 months (range, 45 -91 months). The results showed that liner wear rates were 0.28 mm/year and 107.5 mm3/year. The acetabular component had significantly high clinical wear rates. Care must be taken to avoid osteolysis and to avoid revision THA.

著者関連情報
© 2006 中国・四国整形外科学会
前の記事 次の記事
feedback
Top