環境化学
Online ISSN : 1882-5818
Print ISSN : 0917-2408
ISSN-L : 0917-2408
報文
自動同定定量システム(AIQS)を活用した災害時の環境モニタリング ~東日本大震災での活用と技術的展開~
中島 大介鈴木 剛中山 祥嗣白石 不二雄新田 裕史小山 陽介柳下 真由子宮脇 崇中島 寛則木村 淳子門上 希和夫
著者情報
ジャーナル フリー

2019 年 29 巻 3 号 p. 129-137

詳細
抄録

Automated identification and determination system using a gas chromatograph-mass spectrometry (AIQS-GC) is a technology that enables semi-identification and quantification of substances without using the standard substance. Using this method, environmental water monitoring around the disaster temporary storage area after the Great East Japan Earthquake was conducted. Di (2-ethylhexyl) phthalate, pyrene, etc. were detected at high concentration. Some substances showed high concentration near the temporary storage area, suggesting the possibility of elution from disaster waste. Thus, AIQS-GC was effective in emergency monitoring such as disasters. The authors held several workshops to disseminate this system. We have also started joint research with the local environment research institute on the improvement of AIQS-GC. In this joint research, we have a plan to add the number of listed substances, expand the applicable equipment manufacturers, and study the inter-apparatus and inter-laboratory error. In addition, AIQS can be analyzed retrospectively, accumulated and aggregated measurement data is expected.

著者関連情報
© 2019 一般社団法人 日本環境化学会
前の記事 次の記事
feedback
Top