Journal of Environment and Engineering
Online ISSN : 1880-988X
ISSN-L : 1880-988X
Papers
Dynamic Characteristic of a Fuel Cell Micro-Grid Using an Engine Generator to Base Load Operation
Shin'ya OBARA
著者情報
ジャーナル フリー

2008 年 3 巻 1 号 p. 49-60

詳細
抄録
The dynamic of a micro-grid consisting of an engine generator and sixteen fuel cells was clarified by the transfer function model using actual data from power generators. The micro-grid was composed of a 3kW engine generator and 1kW fuel cells, and the dynamic characteristics of the grid were analyzed using the energy demand model in February of a cold region. Consequently, the settling time (Time taken to converge on ±5% of the limit of an output target) of a micro-grid is 15 seconds from 10 seconds. The control parameter of a fuel cell system is significantly influenced by the settling time and overshooting of a micro-grid. Since any excess and deficiency in electric power can respectively be covered if two or more fuel cells are connected with a grid, the instant electric power demand load peak can be distributed. Compared with the number of fuel cells required when installing independently, the number of installations can be reduced for a micro-grid system.
著者関連情報
© 2008 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback