鉄鉱石中の鉄のけい光X線分析における異常値発生原因の検討
佐々木 稔卯月 淑夫川瀬 平久
著者情報
ジャーナル フリー

1970 年 34 巻 11 号 p. 1151-1155

詳細
抄録

Analytical samples of thirty five sorts of iron ore were prepared by dry and wet crushing methods. Abnormal large values in the analysis of iron were obtained in the following cases: (a) Hematite in the analytical sample made from microcrystalline hematite ore was concentrated in size of below two microns fraction. (b) Goethite in weathered iron ore was preferentially pulverized to the size of below about 0.5 micron. (c) Hard and large crystalline quartz accompanied with iron ore, being not finely pulverized, was gathered in the range of coarse particle of the sample. While, the small value of iron was obtained in the analysis of hard and coarse grained magnetite ore. The occurrence of the abnormal value was considered due to discrepancies in size distributions of powder particles of constituent minerals.
Simillar tendencies were also shown in the analysis of fine powder samples prepared by a wet crushing method.

著者関連情報