Japanese Journal of Food Chemistry and Safety
Online ISSN : 2189-6445
Print ISSN : 1341-2094
ISSN-L : 1341-2094
Notes
Determination of sucralose in foods by HPLC using derivatization
Tomoko YamabeManabu TakemuraYuka KawaguchiYoshiki KimuraShinpei NishiguchiYoshimi Kitada
Author information
JOURNAL FREE ACCESS

2012 Volume 19 Issue 1 Pages 54-58

Details
Abstract
A rapid and sensitive method has been developed for determining of sucralose in various foods by high performance liquid chromatography (HPLC) using derivatization. Sucralose in foods were extracted with water in ultrasonic bath, and the extract was loaded onto a strata-X-C, reverse-phase and cation-exchange cartridge. The HPLC separation was performed on a InertSustain C18 column (5 μm, 4.6 mm i.d. x 150 mm) using acetonitrile-H2O (4:1) as a mobile phase. The injection volume, flow rate and column temperature were 20 μL, 1.0 mL/min and 40℃, respectively. A UV absorbance detector was set to 230 nm. The recoveries of sucralose from foods added at the level 0.2 g/kg and 0.05 g/kg were 75.2-95.6% and 71.6-92.9%, respectively. The recoveries from foods except chewing gum added at the level 0.008 g/kg were 89.0-98.0% and 19.2% in chewing gum. The determination limit was 0.004 g/kg in foods except chewing gum and 0.025 g/kg in chewing gum. Nine commercial foods indicated the using of sucralose were determined by the proposed method. Sucralose was detected in all foods in the range of 0.01-1.26 g/kg. The correlation between the proposed method and the dialysis method was high (correlation coefficient 0.999).
Content from these authors
© 2012 Japanese Society of Food Chemistry
Previous article Next article
feedback
Top