精密機械
Print ISSN : 0374-3543
トルク比一定の歯車に関する研究(第5報)
試作および性能試験
酒井 高男森田 信義
著者情報
ジャーナル フリー

1971 年 37 巻 438 号 p. 522-526

詳細
抄録

It was revealed in the previous paper that the performances of IF gears are superior to those of several kinds of conventional watch gears.
Thereupon it has been tried to apply IF gears to a watch, and the variation rate of torque ratio of both IF gears and the conventional watch gears which were designed for the same watch under the same conditions has been measured.
The results are as follows.
1) The variation rate of torque ratio of IF gears is about 40% less than that of the conventional watch gears.
2) The uniformity of the variation rate of IF gears is better than that of the conventional watch gears.

著者関連情報
© 社団法人 精密工学会
前の記事 次の記事
feedback
Top