抄録
Iron losses measured by a single sheet tester depend on the construction of the yoke. The reason for this is examined by measurement and numerical analysis. The double yoke type single sheet tester is recommended as the standard tester, because the eddy current distributions on the surfaces of the two sides of the specimen are different from each other when the single yoke type tester is used.