ギャップ付きアモルファスカットコアの鉄損低減
福永 博俊江口 徹三田 登茂子太田 幸彦掛橋 英典
著者情報
ジャーナル オープンアクセス

1989 年 13 巻 2 号 p. 375-378

詳細
抄録
In order to reduce core loss in amorphous cut cores with air gaps. the effects of ferrite plates attached to cut surfaces of the cores were investigated. It was earned that the attachment of thin ferrite plates decreases core loss remarkably in amorphous cut cores with air gaps. It has also been discovered that this method of reducing core loss is effective in induction levels up to 0.7 T. Computer simulation of leakage flux in an amorphous cut core with air gaps suggests that this reduction is attributable to decrease of the leakage flux perpendicular to amorphous ribbon surfaces due to the attachment of the ferrite plates.
著者関連情報
© 1989 (社)日本応用磁気学会