応力を非接触測定できる磁気異方性センサの変換理論
岸本  哲英 貢脇若 弘之山田 一
著者情報
ジャーナル オープンアクセス

1991 年 15 巻 2 号 p. 481-484

詳細
抄録
The magnetic anisotropy sensor (MAS) is able to measure the mechanical stress of ferromagnetic material noncontactly. This paper deals with the conversion theory of MAS output voltage utilizing directional permeability distribution that assumed an elliptical form in the specimen. Relative permeability is proportional to the stress. Theoretical expression of the output voltage is derived from the concept of directional permeability distribution. The calculated curves of the output voltage have a comparatively good approach to the measured value due to the change of stress.