Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original Articles
Internal porosities, retentive force, and survival of cobalt-chromium alloy clasps fabricated by selective laser-sintering
Josef SchweigerJan-Frederik GüthKurt-Jürgen ErdeltDaniel EdelhoffOliver Schubert
著者情報
ジャーナル オープンアクセス

2020 年 64 巻 2 号 p. 210-216

詳細
抄録

Purpose: The purpose of this study was to evaluate internal porosities, retentive force values and survival of cobalt-chromium (Co-Cr) alloy clasps fabricated by direct metal laser-sintering (DMLS) and compare them to conventionally cast clasps.

Methods: Embrasure clasps were digitally designed fitting teeth 35 and 36 on identical metal models (N = 32). Sixteen clasps were fabricated using DMLS (group DMLS) and another sixteen clasps were additively manufactured from wax and then cast from a Co-Cr alloy (group CAST). Internal porosities were examined using micro-focus X-ray (micro-CT) and analyzed applying Kolmogorov-Smirnov test, Mann-Whitney test, and T test (significance level: p < 0.050). A universal testing machine was used to determine the retentive force values at baseline and after 1095, 5475, 10,950 and 65,000 cycles of simulated aging. Data were analyzed employing Kolmogorov-Smirnov test, one-way ANOVA, and Scheffé's post-hoc test (significance level: p < 0.050). Survival was estimated for 65,000 cycles of artificial aging using Kaplan-Meier analysis.

Results: Micro-CT analysis revealed a higher prevalence (p < 0.001), but a more homogeneous size and a significantly smaller mean (p = 0.009) and total volume (p < 0.001) of internal porosities for group DMLS. The groups showed mean initial retentive force values of 13.57 N (CAST) and 15.74 N (DMLS), which significantly declined over aging for group CAST (p = 0.003), but not for group DMLS (p = 0.107). Survival was considerably higher for group DMLS (93.8%) than for group CAST (43.8%) after 65,000 cycles of aging.

Conclusions: Clasps made by laser-sintering could be an alternative to conventional cast clasps for the fabrication of removable partial denture frameworks.

著者関連情報

この記事は最新の被引用情報を取得できません。

© 2020 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/
前の記事 次の記事
feedback
Top