Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Original article
Three-dimensional digital evaluation of thickness accuracy of mock-ups fabricated by silicone matrices: An in vitro study
Zhongyi LiHongqiang YeHefei BaiYijiao ZhaoYong WangYuchun Sun Yongsheng Zhou
著者情報
ジャーナル オープンアクセス

2022 年 66 巻 3 号 p. 445-451

詳細
抄録

Purpose: Although mock-ups have been widely used in dental esthetic rehabilitation, their accuracy has not been quantitatively evaluated, and the methods of fabricating mock-ups are various. This in vitro study investigated the thickness accuracy of mock-ups fabricated with different silicone matrices.

Methods: Mock-ups of maxillary anterior teeth were respectively fabricated by 72 silicone matrices that were equally divided into four groups (n=18 for each group) according to two variables of the silicone matrices: labial margin position (equigingival or cover labial gingiva for 1−2 mm) and palatal notches (with or without notches on the palatal side of silicone matrices). The thickness accuracy of the mock-ups was analyzed using 3D scanning and 3D deviation analysis techniques compared with diagnostic waxing. The thickness change ratios of the mock-ups were compared using a two-way analysis of variance (ANOVA). One-way ANOVA and Kruskal-Wallis tests were used to compare differences in thickness change ratios between different teeth in each group.

Results: The thickness accuracy of the mock-ups was significantly affected by the labial margin position and the palatal notches of the silicone matrices, respectively, in the labial area and the incisal area. The most accurate mock-ups were made using silicone matrices with equigingival labial margins and palatal notches. The thickness accuracy of the mock-ups was also inconsistent on different teeth.

Conclusion: The mock-ups fabricated by silicone matrices were thicker than the diagnostic waxing. The application of silicone matrices to equigingival labial margins and palatal notches was beneficial to the thickness accuracy of mock-ups.

著者関連情報
© 2022 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/