Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Retention of zirconia crowns to Ti-base abutments: effect of luting protocol, abutment treatment and autoclave sterilization.
Edmara T. P. Bergamo Abbas ZahouiLarissa Luri Amorin IkejiriManoela MarunKimberly Peixoto da SilvaPaulo G. CoelhoSimone SoaresEstevam A. Bonfante
著者情報
ジャーナル オープンアクセス 早期公開

論文ID: JPOR_2019_537

この記事には本公開記事があります。
詳細
抄録
Purpose: To evaluate the influence of resin cement type, surface pretreatment and autoclave sterilization on the retention of Y-TZP crowns to Ti-base abutments.
Methods: Y-TZP crowns were designed and milled to fit Ti-base abutments. Crowns were cemented using either a conventional resin cement (conventional) with a universal adhesive or a self-adhesive resin cement (self-adhesive), both following no surface pretreatment (No) or Ti-base abutment sandblasting (SB) (n=20/group). Half of the cemented samples were subjected to in-office autoclave sterilization. Pullout testing was performed in a universal testing machine at a speed of 1 mm/min until crown displacement. Data were statistically evaluated through a linear mixed model following post hoc comparisons by LSD test.
Results: Pullout data as a function of cement type demonstrated higher retention for conventional relative to self-adhesive cement (p < 0.001). Ti-base sandblasting (SB) favored crown retentiveness over No pretreatment (p < 0.001). Sterilized crowns exhibited higher pullout values than non-sterile (p=0.036). All the two- and three-factor interaction analyses corroborated with the superior adhesive strength of conventional compared to self-adhesive cement (all, p < 0.011), as well as, SB relative to No pretreatment (all, p < 0.024). While autoclave sterilization maximized bond strength when self-adhesive cement (data collapsed over surface pretreatment, p < 0.050) and No pretreatment were evaluated (data collapsed over surface pretreatment, p < 0.013), no significant difference was observed for conventional resin cement (p=0.280) and SB (p=0.878) groups.
Conclusions: Conventional resin cement and/or Ti-base sandblasting increased Y-TZP crown retentiveness, with no significant influence of autoclave sterilization. Autoclaving increased retentiveness when self-adhesive cement and/or no Ti-base pretreatment were used.
著者関連情報

この記事はクリエイティブ・コモンズ [表示 - 非営利 4.0 国際]ライセンスの下に提供されています。
This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BY-NC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/deed.ja
feedback
Top