Influence of cleaning methods on zirconia ceramic bonding with long-elapsed time post-airborne-particle abrasion
Majed Al-Akhali Eglal Al-DobaeiAbdulaziz SamranAhmed Wagdy HashemSebastian WilleMatthias Kern
著者情報
ジャーナル オープンアクセス 早期公開

論文ID: JPR_D_24_00273

詳細
抄録

Purpose: To evaluate the influence of cleaning methods on bonding to zirconia ceramic over a long period after airborne-particle abrasion (APA).

Methods: A total of 140 disc-shaped zirconia specimens were divided into five groups based on the cleaning methods after a 72-hour delay between APA and bonding: A-(alcohol), V-(Ivoclean), K-(Katana Cleaner), P2-(Clearfil Ceramic Primer Plus after 72 hours), and P1-(Clearfil Ceramic Primer Plus directly after APA). The specimens were APA-treated with 50-µm alumina particles (Al2O3) and stored at room temperature for 72 hours (n=28/group). Surface free energy (SFE) was measured for 12 specimens per group using a goniometer. For each group, 16 Plexiglas tubes filled with composite resin were bonded to zirconia specimens using a self-adhesive luting resin. Tensile bond strength (TBS) was tested for subgroups of eight specimens after 3 days of water storage and 150 days with 37500 thermal cycles. Failure modes were categorized as adhesive or cohesive using light microscopy.

Results: SFE increased significantly in groups V (68.4 mN/m) and A (61.8 mN/m) (P ≤ 0.05), but decreased in group K (33.1 mN/m) (P ≤ 0.05). TBS after 3 days of water storage ranged from 60.7 MPa in group A to 51.6 MPa in group P2 without significant difference between the tested groups (P > 0.05), and after 150 days with thermocycling, it ranged from (45.4 MPa) in group K to 33.9 MPa in group P2 with a significant difference between groups K and P2 (P ≤ 0.05).

Conclusions: Cleaning significantly affected the strength and durability of bonding in non-retentive zirconia restorations when there was a considerable time gap between APA and bonding.

著者関連情報
© 2025 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution-NonCommercial License 4.0 (CC BYNC 4.0), which allows users to distribute and copy the material in any format as long as credit is given to the Japan Prosthodontic Society. It should be noted however, that the material cannot be used for commercial purposes.
https://creativecommons.org/licenses/by-nc/4.0/