論文ID: JPR_D_24_00278
Purpose: Supports are essential for ensuring dimensional accuracy in 3D printing; however, an excessive number of supports compromises printing efficiency. This study aimed to investigate how a varying number of support arrangements affects the precision and trueness of 3D-printed dentures.
Methods: Three denture base printing files were designed, each with different numbers of supports: 40 (group 40), 55 (group 55), and 70 (group 70). Thirty samples were printed and measured across the groups. Accuracy was evaluated by assessing trueness and precision using the root mean square error (RMSE). The error areas in each group were analyzed through micro-computed tomography (micro-CT) 3D imaging.
Results: Group 70 showed a significantly lower RMSE for trueness than Group 40 (P < 0.05), but showed no significant difference from Group 55 (P ≥ 0.05). For precision, Group 70 outperformed both Groups 40 and 55 (P < 0.05), which did not differ significantly (P ≥ 0.05). Micro-CT revealed no mismatches in the palatal region. Discrepancies—areas where the supports in Groups 40 and 55 did not accurately align with those in Group 70—were predominantly observed at initiation points of overhangs in thinner sections.
Conclusions: Based on these results, this study recommends placing support structures strategically around overhangs and thin-walled areas to enhance the accuracy of 3D-printed denture fabrication. These findings indicate that optimizing support placement, rather than merely increasing the number of supports, is crucial in improving the quality and reliability of 3D-printed dental prostheses.