新しいアンモニア吸着剤を用いた透析液再生式人工腎臓
屋ケ田 和彦大坪 修堀内 孝石川 州洋内間 高夫山内 潤山田 豊高井 信次高橋 浩稲生 綱政
著者情報
ジャーナル フリー

1981 年 10 巻 1 号 p. 73-76

詳細
抄録
A new type siliceous adsorbent for ammonium ion was used for the dialysate regneration system.
This system is based upon the use of activated charcoal, alumina, urease, and the siliceous adsorbent for ammonium ion named ZEC-50. Waste products (Creatinine, Urea, Phosphate) was succesfully removed from 5-liters of dialysate in an anephric dog with this system. However, for a clinical demonstration it is thought to be necessary to improve the adsorbent for ammonium ion, because a large volume of adsorbent of ZEC-50 is needed according to its capacity of ammonium ion.
As a result of adsorption tests, it suggests that MORDENITE will be one of good adsorbents for ammonium ion in a new type dialysate regeneration system.