Journal of Advanced Science
Online ISSN : 1881-3917
Print ISSN : 0915-5651
ISSN-L : 0915-5651
イオン交換膜利用淡海水直接発電 (DB発電)
長期間使用による出力電力の劣化
Megumi OKABETomomi HOSHINOFujio SUDASadao UEGUSA
著者情報
ジャーナル フリー

1999 年 11 巻 2 号 p. 113-114

詳細
抄録

A dialytic battery (DB) with ion-exchange membranes can convert the mixing free energy into the electric energy. The purpose of this paper is in seeing the deterioration of the performance by use of long time of an ion exchange film. Maximum electric power became about 1/10 in carbon electrode by the use of intermittence which lasted for eight years.

著者関連情報
© Society of Advanced Science
前の記事 次の記事
feedback