日本太陽エネルギー学会講演論文集
Online ISSN : 2758-478X
2024年度(令和6年度)研究発表会
会議情報

セッション:A3 太陽光発電システム(応用技術Ⅰ)
42 PV大量導入時における送電線の停電作業計画のための過酷条件分析
*鈴木 雅之加藤 大樹森 友輔若尾 真治山嵜 朋秀豊嶋 伊知郎犬塚 直也
著者情報
会議録・要旨集 フリー

p. 143-146

詳細
抄録

Proper assumption of severe load conditions is necessary in transmission line outage work planning. In recent years, renewable energy sources such as PV have been introduced into the grid in large quantities, and grid congestion caused by the large introduction of the power sources and uncertainty has become an issue, making it difficult to assume loads that satisfy the severe conditions. In this paper, a power system model with a large amount of PV is created, and optimal tidal flow calculations are performed using the severe condition as the objective function to analyze the adequate severe condition, which will contribute to future outage work planning.

著者関連情報
© 一般社団法人日本太陽エネルギー学会
前の記事 次の記事
feedback
Top