膨張破砕剤による尿路結石破砕の基礎実験
河内 明宏渡辺 泱内田 睦中河 裕治藤戸 章北村 浩二今出 陽一朗
著者情報
ジャーナル フリー

1987 年 25 巻 4 号 p. 255-259

詳細
抄録
The possibility of expansive splitter used in general industry for the application to lithotripsy was evaluated experimentally. The result were as follows,
1) Expansive stress generated by expansive splitter was enough to cause all urinary stones to crack.
2) Urinary caluculus 35×30×30mm in size was fragmented within 30 minutes.
3) The spherical model caluculi 30mm in diameter were fragmented in a condition that the boring size was more than one fifth of the diameter and the boring depth was more than a half of it.
The results suggested that expansive splitter could be applied clinically to fragment urinary caluculi after some improvements.