JSME International Journal Series A Solid Mechanics and Material Engineering
Online ISSN : 1347-5363
Print ISSN : 1344-7912
ISSN-L : 1344-7912
PAPERS
Fatigue Failure by In-line Flow-induced Vibration and Fatigue Life Evaluation
Satoru ODAHARAYukitaka MURAKAMIMasahiro INOUEAtsuo SUEOKA
著者情報
ジャーナル フリー

2005 年 48 巻 2 号 p. 109-117

詳細
抄録
The phenomenon of fatigue failure due to In-line flow-induced vibration has been investigated. In the experimental program an induced-vibration experimental set-up involving water flow was developed. This apparatus was used to produce fatigue failure resulting from In-line flow-induced vibration. The fatigue specimens were made of a medium carbon steel. A small hole was drilled into the specimen surface to localize the fatigue cracking process. A strain histogram recorder (Mini Rainflow Corder, MRC) was used to acquire the service strain histogram and also to detect any variations in natural frequency. The cumulative fatigue damage, D, as defined by the Modified Miner Rule, was determined by using the strain histogram of the early portion of the test record. The value of D was almost unity in the case of In-line vibration. In contrast, the value of D obtained in a previous investigation for the case of the Cross-flow vibration ranged approximately from 0.2 to 0.8.
著者関連情報
© 2005 by The Japan Society of Mechanical Engineers
前の記事
feedback
Top