JSME International Journal Series B Fluids and Thermal Engineering
Online ISSN : 1347-5371
Print ISSN : 1340-8054
ISSN-L : 1340-8054
Dryout in a Boiling Channel under Oscillatory Flow Condition
Hisashi UMEKAWAMamoru OZAWAAkira MIYAZAKIKaichiro MISHIMATakashi HIBIKI
著者情報
ジャーナル フリー

1996 年 39 巻 2 号 p. 412-418

詳細
抄録
Premature dryout due to flow oscillation is a very important factor in designing boiling systems. The flow oscillation depends, in general, on system size and/or configuration, and therefore the relationship between the premature dryout and the flow oscillation has not been fully understood so far. In this investigation, a CHF experiment in a forced flow boiling channel under the oscillatory flow condition has been conducted. Numerical simulation has also been conducted based on the lumped-parameter model of the boiling channel. The simulation well represents the transient behavior of the dryout under the oscillatory flow condition.
著者関連情報
© The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top