JSME International Journal Series C Mechanical Systems, Machine Elements and Manufacturing
Online ISSN : 1347-538X
Print ISSN : 1344-7653
ISSN-L : 1344-7653
PAPERS
A Fast Evaluation Approach of Geometrical Correspondence Uncertainty for 3-D Vision Measurement System
Ming-June TSAIChuan-Cheng HUNG
著者情報
ジャーナル フリー

2006 年 49 巻 2 号 p. 527-534

詳細
抄録

This paper addresses an approach for fast evaluation approach of correspondence uncertainty in 3-D vision metrology systems. The mathematic model of spatial resolution measurement area of a 3-D active vision system is developed from the calibrated system parameters. Using the derived model, error of correspondence matching between digital micro-mirrors device (DMD) and charge coupled device (CCD) camera is analyzed. Moreover, a performance index, expressed in terms of correspondence uncertainty, is used for evaluation of the upper and lower bound of resolution. In order to verify the proposed evaluation approach, a precision surface measurement system is established and calibrated. Our analysis shows that the upper part of the measurement area has the smallest correspondence uncertainty, which agrees well with the real physical arrangement. The variation of correspondence uncertainty within the measurement area is around 60.96%. Furthermore, based on the theoretical analysis of uncertainty bounds, an experimental measurement on gauge block was carried out and validated the method.

著者関連情報
© 2006 by The Japan Society of Mechanical Engineers
前の記事 次の記事
feedback
Top