Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 244
会議情報
244 天井懸架型手術顕微鏡のアクティブ微振動制御装置
藤田 隆史山田 直秀嶋崎 守安田 正志洞 宏一土家 正樹
著者情報
会議録・要旨集 フリー

詳細
抄録
It has been a problem in some hospitals that operations using surgical microscopes of suspension type become more difficult due to microvibrations of the microscopes caused by human walks and building equipment such as air conditioning machines. For a practical solution to it, an active microvibration control system was developed, in which magnetostrictive actuators were used because of their large stiffness. A control law based on a model matching method was used to control of microvibrations of the microscopes having various dynamic characteristics corresponding to their attitudes. Tests showed that the microvibration control system using the control law was effective.
著者関連情報
© 2003 一般社団法人 日本機械学会