Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 616
会議情報
616 原子力発電所蒸発管内探傷ケーブルに発生する摩擦振動 : モックアップによる実験結果(ケーブルの振動,OS-8 振動基礎(2))
中野 寛井上 卓見末岡 淳男村上 敬宜
著者情報
会議録・要旨集 フリー

詳細
抄録
The eddy current testing cable is used for inspection of thickness of evaporator tube in Monjyu (fast breeder reactor). This paper deal with the vibration noise of ECT cable generating when this cable is inserted or pulled back in the evaporator tube. We experimented with mock-up and examined characteristic of vibration noise of ECT cable. This experiment showed the vibration noise in inserting ECT cable was bigger than that in pulling back it and the frequencies of vibration were converged on one. We confirmed the countermeasure for ECT cable could control the vibration noise in radial direction of evaporator tube.
著者関連情報
© 2004 一般社団法人 日本機械学会