245 微少生体細胞に対する動的理学刺激の付加および評価システムの開発
今野 健一小沢田 正木嶋 浩之阿久津 真登
著者情報
会議録・要旨集 フリー

詳細
抄録
In this study, a new non-invasive micro sensor system is developed to detect compliance of minute living cells and tissues by using dynamic response of piezoelectric vibrator. 3-D micro actuator is also developed to initiate dynamic stimulations. The sensor was controlled by micromanipulator system, while dimensions and morphologies of the cells were measured by inverted phase contract microscope system. The method has shown that the reaction of living cells might have frequency dependence against vibrating stimulations by the actuator. Also, experimental studies have shown sensor's capability to detect mechanical properties of minute living cells.