Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 312
会議情報
312 遠心圧縮機による配管内圧力脈動に関する研究
林 慈朗金子 成彦
著者情報
会議録・要旨集 フリー

詳細
抄録
Pressure pulsations excited by centrifugal compressors or blowers at blade-passing frequency may cause severe noise and vibrations in piping systems. Therefore, the establishment of a practical evaluation method for pressure pulsations is desired so as to prevent such problems. In this study, one dimensional excitation source model in a compressor was proposed based on the equation of motion. It is shown that the relation between the maximum pressure amplitude in piping systems and the location of an excitation source under resonant condition can be evaluated by introducing the equivalent resistance of a compressor and piping systems.
著者関連情報
© 2006 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top