Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 556
会議情報
556 高速応答型層流式流量計を用いた往復動型内燃機関のサイクル毎吸気流量計測
鹿ノ戸 義彦永井 健一郎賀羽 常道飯田 訓正
著者情報
会議録・要旨集 フリー

詳細
抄録
In resent years, higher combustion efficiency and lower emissions are required in engine development and therefore higher combustion control is necessary. To realize higher combustion control in reciprocating engine, cycle to cycle flow rate measurement is important. Especially it is a key factor to control HCCI combustion. Traditional laminar flow meter has a problem with response. However, fast response differential pressure transducer allows cycle to cycle dynamical flow measurement. The availability of Fast-response Laminar Flow Meter on cycle-to-cycle flow rate measurement is shown in this paper.
著者関連情報
© 2008 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top