Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 552
会議情報
552 自励振動を用いた3次の非線形弾性測定装置
國分 陽介, 藪野 浩司, 黒田 雅治, 山本 泰之
著者情報
会議録・要旨集 フリー

詳細
抄録
This paper proposes the measurement system of cubic nonlinear elasticity of tissues. The system consists of a vibrator, a measuring object and a control circuit. We apply a nonlinear feedback proportional to velocity and displacement squared of the vibrator to actuate the vibrator for inducing van der Pol type self-excited oscillation and control the amplitude of the oscillation by changing the nonlinear feedback gain. When the vibrator touches the measuring object, the frequency shift of the vibrator occurs depending on elasticity of the object. When the object has nonlinear elasticity, it causes a natural frequency shift related to the amplitude of the vibrator. Therefore, by the change of the response amplitude based on the variation of the nonlinear feedback gain, we estimate the nonlinear elasticity of the object. We theoretically examine the validity of the above proposed measurement method for the cubic nonlinear elasticity of the object and experimentally confirm the performance for the cubic nonlinear elasticity of the system with magnetic restoring force.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事