Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 418
会議情報

旋回失速に起因する超低周波音の対策に関する研究
*石原 国彦長嶋 達也多賀 智治
著者情報
会議録・要旨集 フリー

詳細
抄録

An infrasound sometimes occurs in an industrial field like a paper factory and it becomes a cause of complaints from neighborhood resident of the factory. The infrasound has acoustic features of a long wave length and little effects of conventional countermeasures such as an acoustic absorbent and sound insulator. Therefore once it happens, it has been difficult to do countermeasure. This paper describes that the rotating stall occurred in a fan (IDF: Induced Fan) becomes the cause of the infrasound generated from the EP (Electric dust collector) set in the factory. This is a very scarce and interesting phenomenon. So it is considered of value to describe the event. A lot of measurements were carried out to clarify the cause of this event. As a result, the cause of the infrasound is the resonance of the EP and the cause of the resonance is the rotating stall of the fan. Therefore the countermeasure is to exchange a new fan with P-Q characteristics of a large gradient ( ∂p / ∂Q ).As a result, the infrasound disappeared.

著者関連情報
© 2018 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top