Dynamics & Design Conference
Online ISSN : 2424-2993
セッションID: 303
会議情報

上部圧縮機設置型冷蔵庫のねじり振動要因分析と低減手法について
*柴原 知里宮本 洋輔吉田 準史
著者情報
会議録・要旨集 認証あり

詳細
抄録

In this study, we attempted to decrease door vibration of a refrigerator in which the compressor was installed at top area for good usability. Through the operational test, the door vibration was found to be large at 18 rps. For the factor analysis, vibration mode analysis and operational transfer path analysis were applied. The result showed that the refrigerator twist mode at 18 Hz and the compressor vibration behavior along left-right direction were observed to be the main factor increasing the door vibration at 18 rps. Then, we inserted a steel plate between the compressor and the body along left-right direction to constrain the compressor vibration along the direction. As the result, the door could be reduced decreased largely effectively by the attachment of the bar.

著者関連情報
© 2021 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top