322 オゾン耐性膜による高効率高度処理
水野 健一郎峯岸 寅太郎藤井 康二郎中谷 健治高橋 和孝
著者情報
会議録・要旨集 フリー

p. 269-272

詳細
抄録
On advanced drinking water treatment, including unit processes of ozonation, ozone resistant membrane filtration and granular activated carbon (GAC) tower treatment, pollutant removal performances of unit processes and relationships between some operational conditions and membrane filtration flux were examined. From the experimental results, it became obvious that it was necessary to maintain residual ozone concentration of 0.2 to 1.0mg/L in the filtrate from the membrane module in order to maintain higher membrane filtration flux. With ozone dosage of 3mg/L by an ejector and with operation mode of dead-end filtration, membrane filtration flux of more than 5m^3/M^2/day could be maintained. Quality of the effluent from GAC tower constantly satisfied Japanese standard for drinking water.