環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
会議情報
320 軸流型サイクロン分離器の分離性能向上のための二次噴流の効果の研究
安蔵 英紀松川 泰教秋山 圭介小川 明
著者情報
会議録・要旨集 フリー

p. 370-373

詳細
抄録
Uni-flow cyclone dust collector is applied to the separation of particles from air and gases. This equipment could not be expected a high collection efficiency. So in this report, effect of secondary jet was investigated to promote separation efficiency. And its collection efficiency and the pressure drop depended on the velocity of secondary jet as a variable were measured. Velocity V_2 of secondary jet was determined as 13.7,18.5,23.8,27.0 28.4 (m/s), and velocity V_1 of main flow was determined as 3.0,6.0,9.0,12.0,15.0 (m/s). Therefore in this report, the boss diameter was Db=47 (mm), the form of guide vane was plate type of fixed guide vane. and dust was used Fly-Ash, the average particle diameter was X_<50>=5.57 (μ m). and the dust was measured by Andreasen pipette method, This experiment was acted the condition.
著者関連情報
© 2002 一般社団法人 日本機械学会