環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 205
会議情報
水冷式ストーカの実機導入運転性能評価(燃焼・ガス化(1),廃棄物処理技術)
宮田 治男鈴木 厚志河合 宏廷
著者情報
会議録・要旨集 フリー

詳細
抄録
The first Water-cooled grates system, the most important key technology for Next generation stoker incinerator, was applied to an existing commercial waste incineration plant in Japan to demonstrate its operation performance Following results were confirmed for one-year incineration operation. (1)Surface temperature of the gates could be kept less than 70 degree-C and the long term stabilized incineration was confirmed by a sufficient cooling effect. (2)Abrasion loss of the gates was less than 0.5 mm for one-year operation and excellent durability was confirmed. (3)Stable operation with 8% O2 concentration in the flue gas at SCR outlet was confirmed with flue gas recirculation. (4)CO concentration in the flue gas could be kept at a low level sufficiently by mixing effect of flue gas recirculation as a part of secondary combustion air. (5)15% reduction of the flue gas emission was confirmed in case of flue gas recirculation.
著者関連情報
© 2004 一般社団法人 日本機械学会