環境工学総合シンポジウム講演論文集
Online ISSN : 2424-2969
セッションID: 403
会議情報
403 自立駆動型熱サイフォンの駆動特性(新エネルギー(1))
萩野 直人吉田 博夫
著者情報
会議録・要旨集 フリー

詳細
抄録
The thermosyphon can operate without an external power supply, and has simple structure. Therefore, thermosyphon can reduce energy consumption and CO_2 emissions. Ito et al. developed a device in which the reservoir and the condenser are separated. Using this device, it was possible to drastically reduce the time ofonset circulation. The solar input energy varies time to time. Therefore, the start-up condition of the system and the transient behavior against varying heat input are important sut!jects and those were studied in this paper. The main results are as following. First, thermosyphon showed good response to the stepwise variation with 200W amplitude. Second, thermosyphon can be driven by the heat input as low as 40 W.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top