抄録
Based on the example of the open industrial Ethernet Technology standard 'EtherCAT', the paper discusses the influence of superior communication performance on precision, throughput, mechanical lifetime, costs and raw material saving of manufacturing equipment. Several practical examples are shown. It also shows how bandwidth usage, switch delays and stack processing times limit the usage of classical Ethernet for control applications and briefly introduces the EtherCAT communication technology itself.