年次大会
Online ISSN : 2424-2667
ISSN-L : 2424-2667
セッションID: G060061
会議情報
G060061 C2スワンバンドの発光分光法による火炎温度の診断([G06006]熱工学部門一般セッション(6)二燃焼の分光計測および輻射)
品川 手児奈橋本 英樹古川 純一
著者情報
会議録・要旨集 フリー

詳細
抄録
To explore behavior of near extinction flamelets in turbulent premixed flames, emission intensities of OH, CH and C2 radicals of hydrocarbon-air premixed flames have been examined using the newly developed emission spectroscopy system. It has been shown in our previous study that the emission intensity ratio of 515nm/470nm bans of C2 radical uniquely depends on the temperature of unstained methane/air and propane/air flames. In the present study, dependence of the emission intensity ratio of 515nm/470nm bans of C2 radical on the strain rate has been examined using a counter flow burner. As the strain rate increases, both the flame temperature and the emission intensities of C2 radical decreases. The flame temperature monotonically decreases as the emission intensity ratio of 515nm/470nm bans of C2 radical decreases. It is concluded that the temperature of a flamelet of turbulent premixed flames can be estimated by measuring the emission intensity ratio of 515nm/470nm bans of C2 radical.
著者関連情報
© 2011 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top