2940 T 継ぎ手配管の破壊挙動に及ぼす局所減肉の影響
加藤 彰彦高橋 宏治木村 祐介安藤 柱久恒 眞一長谷川 邦夫
著者情報
会議録・要旨集 フリー

p. 455-456

詳細
抄録
To investigate the fracture behavior of Tee pipe with local wall thinning, four point bending tests were carried out using a Tee pipe with local wall thinning without internal pressure. Local wall thinning part is subjected either tensile or compressive stress. Three-dimensional elasto-plastic analyses were also carried out for the Tee pipe with local wall thinning by using Finite Element Method. It has been found that the fracture type is classified into ovalization or local buckling. However, the local wall thinning had no significant effect on the plastic collapse load.